v-plex kits Search Results


99
KCAS Bioanalytical and Biomarker Services kcas bio analytical
Kcas Bio Analytical, supplied by KCAS Bioanalytical and Biomarker Services, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/kcas bio analytical/product/KCAS Bioanalytical and Biomarker Services
Average 99 stars, based on 1 article reviews
kcas bio analytical - by Bioz Stars, 2026-05
99/100 stars
  Buy from Supplier

90
Meso Scale Diagnostics LLC multiplex v-plex kits
Multiplex V Plex Kits, supplied by Meso Scale Diagnostics LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/multiplex v-plex kits/product/Meso Scale Diagnostics LLC
Average 90 stars, based on 1 article reviews
multiplex v-plex kits - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Meso Scale Diagnostics LLC msd meso scale v-plex assay kits
Msd Meso Scale V Plex Assay Kits, supplied by Meso Scale Diagnostics LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/msd meso scale v-plex assay kits/product/Meso Scale Diagnostics LLC
Average 90 stars, based on 1 article reviews
msd meso scale v-plex assay kits - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Meso Scale Diagnostics LLC custom ten-analyte mesoscale v-plex plus kits
Custom Ten Analyte Mesoscale V Plex Plus Kits, supplied by Meso Scale Diagnostics LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/custom ten-analyte mesoscale v-plex plus kits/product/Meso Scale Diagnostics LLC
Average 90 stars, based on 1 article reviews
custom ten-analyte mesoscale v-plex plus kits - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Meso Scale Diagnostics LLC v-plex elisa kits ba.1 spike antigens
V Plex Elisa Kits Ba.1 Spike Antigens, supplied by Meso Scale Diagnostics LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/v-plex elisa kits ba.1 spike antigens/product/Meso Scale Diagnostics LLC
Average 90 stars, based on 1 article reviews
v-plex elisa kits ba.1 spike antigens - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Meso Scale Diagnostics LLC u-plex proinflam combo 1
U Plex Proinflam Combo 1, supplied by Meso Scale Diagnostics LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/u-plex proinflam combo 1/product/Meso Scale Diagnostics LLC
Average 90 stars, based on 1 article reviews
u-plex proinflam combo 1 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Meso Scale Diagnostics LLC custom mouse v-plex elisa kits
Custom Mouse V Plex Elisa Kits, supplied by Meso Scale Diagnostics LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/custom mouse v-plex elisa kits/product/Meso Scale Diagnostics LLC
Average 90 stars, based on 1 article reviews
custom mouse v-plex elisa kits - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Meso Scale Diagnostics LLC custom v-plex meso scale discovery kits
Summary of included studies
Custom V Plex Meso Scale Discovery Kits, supplied by Meso Scale Diagnostics LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/custom v-plex meso scale discovery kits/product/Meso Scale Diagnostics LLC
Average 90 stars, based on 1 article reviews
custom v-plex meso scale discovery kits - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Meso Scale Diagnostics LLC msd human aβ v-plex kits
Summary of included studies
Msd Human Aβ V Plex Kits, supplied by Meso Scale Diagnostics LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/msd human aβ v-plex kits/product/Meso Scale Diagnostics LLC
Average 90 stars, based on 1 article reviews
msd human aβ v-plex kits - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Meso Scale Diagnostics LLC solid-matrix assay msd v-plex ® kits
Dynamic ranges of the Luminex bead-based fluorescence (LMX) and <t>Meso</t> <t>Scale</t> <t>Discovery</t> electrochemiluminescence (MSD) multiplex cytokine immunoassay kits. Ranges of quantification were determined on standard calibration curves. With 3 exceptions (ie, IFN-γ, IL-8, and IL-21), the low-end of the remaining 16/19 shared analytes’ dynamic ranges was lower with the MSD platform compared to the LMX <t>assay.</t> Conversely, and with 2 exceptions (ie, IL-17A and IL-21), the high-end of the dynamic range was greater with the LMX assay versus the MSD assay. In 2 instances (IL-4 and IL-10), the differences in both upper and lower quantification levels differed by at least an order of magnitude between the 2 assays.
Solid Matrix Assay Msd V Plex ® Kits, supplied by Meso Scale Diagnostics LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/solid-matrix assay msd v-plex ® kits/product/Meso Scale Diagnostics LLC
Average 90 stars, based on 1 article reviews
solid-matrix assay msd v-plex ® kits - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Meso Scale Diagnostics LLC msd electrochemiluminescence v-plex cytokine kits
Dynamic ranges of the Luminex bead-based fluorescence (LMX) and <t>Meso</t> <t>Scale</t> <t>Discovery</t> electrochemiluminescence (MSD) multiplex cytokine immunoassay kits. Ranges of quantification were determined on standard calibration curves. With 3 exceptions (ie, IFN-γ, IL-8, and IL-21), the low-end of the remaining 16/19 shared analytes’ dynamic ranges was lower with the MSD platform compared to the LMX <t>assay.</t> Conversely, and with 2 exceptions (ie, IL-17A and IL-21), the high-end of the dynamic range was greater with the LMX assay versus the MSD assay. In 2 instances (IL-4 and IL-10), the differences in both upper and lower quantification levels differed by at least an order of magnitude between the 2 assays.
Msd Electrochemiluminescence V Plex Cytokine Kits, supplied by Meso Scale Diagnostics LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/msd electrochemiluminescence v-plex cytokine kits/product/Meso Scale Diagnostics LLC
Average 90 stars, based on 1 article reviews
msd electrochemiluminescence v-plex cytokine kits - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Meso Scale Diagnostics LLC mouse v-plex electrochemiluminescence kits for ifn-γ
Dynamic ranges of the Luminex bead-based fluorescence (LMX) and <t>Meso</t> <t>Scale</t> <t>Discovery</t> electrochemiluminescence (MSD) multiplex cytokine immunoassay kits. Ranges of quantification were determined on standard calibration curves. With 3 exceptions (ie, IFN-γ, IL-8, and IL-21), the low-end of the remaining 16/19 shared analytes’ dynamic ranges was lower with the MSD platform compared to the LMX <t>assay.</t> Conversely, and with 2 exceptions (ie, IL-17A and IL-21), the high-end of the dynamic range was greater with the LMX assay versus the MSD assay. In 2 instances (IL-4 and IL-10), the differences in both upper and lower quantification levels differed by at least an order of magnitude between the 2 assays.
Mouse V Plex Electrochemiluminescence Kits For Ifn γ, supplied by Meso Scale Diagnostics LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/mouse v-plex electrochemiluminescence kits for ifn-γ/product/Meso Scale Diagnostics LLC
Average 90 stars, based on 1 article reviews
mouse v-plex electrochemiluminescence kits for ifn-γ - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

Image Search Results


Summary of included studies

Journal: Neuro-Oncology Advances

Article Title: Prediagnostic biomarkers for early detection of glioma—using case–control studies from cohorts as study approach

doi: 10.1093/noajnl/vdac036

Figure Lengend Snippet: Summary of included studies

Article Snippet: 2018 , Brenner et al. , USA , Nested case–control study , 457 cases and 457 matched controls , Median: 15 y, interquartile range: 9–21 y , 14 cytokines , Four sensitive custom V-PLEX Meso Scale Discovery kits (MSD) and 1 standard MSD kits , IL-15 and IL-16 were inversely associated with glioma risks..

Techniques: Biomarker Discovery, Genome Wide, Amplification, Clinical Proteomics, Enzyme-linked Immunosorbent Assay, Ab Array, Multiplex Assay, Concentration Assay, Luminex

Dynamic ranges of the Luminex bead-based fluorescence (LMX) and Meso Scale Discovery electrochemiluminescence (MSD) multiplex cytokine immunoassay kits. Ranges of quantification were determined on standard calibration curves. With 3 exceptions (ie, IFN-γ, IL-8, and IL-21), the low-end of the remaining 16/19 shared analytes’ dynamic ranges was lower with the MSD platform compared to the LMX assay. Conversely, and with 2 exceptions (ie, IL-17A and IL-21), the high-end of the dynamic range was greater with the LMX assay versus the MSD assay. In 2 instances (IL-4 and IL-10), the differences in both upper and lower quantification levels differed by at least an order of magnitude between the 2 assays.

Journal: Biomarker Insights

Article Title: Cytokine Profiling in Plasma from Patients with Brain Tumors Versus Healthy Individuals using 2 Different Multiplex Immunoassay Platforms

doi: 10.1177/11772719211006666

Figure Lengend Snippet: Dynamic ranges of the Luminex bead-based fluorescence (LMX) and Meso Scale Discovery electrochemiluminescence (MSD) multiplex cytokine immunoassay kits. Ranges of quantification were determined on standard calibration curves. With 3 exceptions (ie, IFN-γ, IL-8, and IL-21), the low-end of the remaining 16/19 shared analytes’ dynamic ranges was lower with the MSD platform compared to the LMX assay. Conversely, and with 2 exceptions (ie, IL-17A and IL-21), the high-end of the dynamic range was greater with the LMX assay versus the MSD assay. In 2 instances (IL-4 and IL-10), the differences in both upper and lower quantification levels differed by at least an order of magnitude between the 2 assays.

Article Snippet: The second platform was the electrochemiluminescence-based Meso Scale Discovery solid-matrix assay (MSD V-Plex ® kits; Meso Scale Discovery, LLC, Rockville, MD).

Techniques: Luminex, Fluorescence, Electrochemiluminescence, Multiplex Assay

Proportion of donor plasma samples inside the assay quantification range for the Luminex (LMX) and Meso Scale Discovery (MSD) multiplex cytokine immunoassay kits. With the LMX system, all of the 19 shared cytokines were quantifiable in 100% of samples tested. Although the MSD assay had a LLoQ below that of the LMX assay for 17/19 (89) common analytes in earlier standard curve performance evaluations, this sensitivity did not directly translate to evaluating cytokines in human plasma samples. The MSD platform detected and quantified 7 of 19 analytes (37%) in 100% of plasma samples. The MSD assay detection/quantification rate for MIP-1α, IL-12p70, IL-1β, IL-17A, and IFN-γ in samples was 96%, 90%, 86%, 76%, and 75%, respectively. The MSD detection rate was <75% in the remaining 7 of 19 (37%) analytes, including a 0% detection rate for IL-21 and a 8% detection rate for IL-23. Asterisks indicate significant differences for 11/19 analytes between MSD and LMX by Fisher Exact test, with “*” indicating P < .05, “**” indicating P < .01, and “***” indicating P < .001. No asterisk indicates mathematically similar detection frequencies between platforms for those cytokines.

Journal: Biomarker Insights

Article Title: Cytokine Profiling in Plasma from Patients with Brain Tumors Versus Healthy Individuals using 2 Different Multiplex Immunoassay Platforms

doi: 10.1177/11772719211006666

Figure Lengend Snippet: Proportion of donor plasma samples inside the assay quantification range for the Luminex (LMX) and Meso Scale Discovery (MSD) multiplex cytokine immunoassay kits. With the LMX system, all of the 19 shared cytokines were quantifiable in 100% of samples tested. Although the MSD assay had a LLoQ below that of the LMX assay for 17/19 (89) common analytes in earlier standard curve performance evaluations, this sensitivity did not directly translate to evaluating cytokines in human plasma samples. The MSD platform detected and quantified 7 of 19 analytes (37%) in 100% of plasma samples. The MSD assay detection/quantification rate for MIP-1α, IL-12p70, IL-1β, IL-17A, and IFN-γ in samples was 96%, 90%, 86%, 76%, and 75%, respectively. The MSD detection rate was <75% in the remaining 7 of 19 (37%) analytes, including a 0% detection rate for IL-21 and a 8% detection rate for IL-23. Asterisks indicate significant differences for 11/19 analytes between MSD and LMX by Fisher Exact test, with “*” indicating P < .05, “**” indicating P < .01, and “***” indicating P < .001. No asterisk indicates mathematically similar detection frequencies between platforms for those cytokines.

Article Snippet: The second platform was the electrochemiluminescence-based Meso Scale Discovery solid-matrix assay (MSD V-Plex ® kits; Meso Scale Discovery, LLC, Rockville, MD).

Techniques: Luminex, Multiplex Assay

Correlation analysis of concentrations of the 19 cytokines measured in 27 human plasma samples from patients with glioblastoma by the Luminex (LMX) and Meso Scale Discovery (MSD) multiplex assays. Log 2 values of MSD/LMX concentration ratios are shown on the y -axis, and estimate systematic measurement differences between methods when the mean value deviates from zero. A negative shift of the blue mean indicates that the MSD assay classifies the analyte at concentrations lower than LMX, and vice versa. The red ±1.96 SD lines represent 95% limits of agreement, and when SDs are large or n-values are low, then interpretation can be ambiguous. For 17 of 19 shared analytes, the mean concentration ratio was shifted to a positive value, indicating that LMX classified the target cytokine in identical plasma samples at a higher concentration than MSD. The sole exception was with MIP-1β, where MSD characterized samples as containing markedly higher concentrations of cytokine than LMX. Analyte-concentration-dependent effects were suggested by the slope of the mean line, and were notable for IL-7 and MIP-1β. The only cytokine similarly characterized by both assays was IL-8.

Journal: Biomarker Insights

Article Title: Cytokine Profiling in Plasma from Patients with Brain Tumors Versus Healthy Individuals using 2 Different Multiplex Immunoassay Platforms

doi: 10.1177/11772719211006666

Figure Lengend Snippet: Correlation analysis of concentrations of the 19 cytokines measured in 27 human plasma samples from patients with glioblastoma by the Luminex (LMX) and Meso Scale Discovery (MSD) multiplex assays. Log 2 values of MSD/LMX concentration ratios are shown on the y -axis, and estimate systematic measurement differences between methods when the mean value deviates from zero. A negative shift of the blue mean indicates that the MSD assay classifies the analyte at concentrations lower than LMX, and vice versa. The red ±1.96 SD lines represent 95% limits of agreement, and when SDs are large or n-values are low, then interpretation can be ambiguous. For 17 of 19 shared analytes, the mean concentration ratio was shifted to a positive value, indicating that LMX classified the target cytokine in identical plasma samples at a higher concentration than MSD. The sole exception was with MIP-1β, where MSD characterized samples as containing markedly higher concentrations of cytokine than LMX. Analyte-concentration-dependent effects were suggested by the slope of the mean line, and were notable for IL-7 and MIP-1β. The only cytokine similarly characterized by both assays was IL-8.

Article Snippet: The second platform was the electrochemiluminescence-based Meso Scale Discovery solid-matrix assay (MSD V-Plex ® kits; Meso Scale Discovery, LLC, Rockville, MD).

Techniques: Luminex, Multiplex Assay, Concentration Assay